BNZ capacitors are made to order only, for your circuit and
physical specifications. The housings are phenolic, with square or
rectangular cross-sections. They may be connected in series or parallel
to withstand extremely high voltages or produce very large capacitance
values. Type BNZ capacitors are designed for high frequency voltages, in
the radio frequency range or below.
1. Voltage range of up to 100 KV, RMS
2. Temperature range of up to 105°C.
Type BNZ capacitors can be supplied with or without an
integral footed mounting plate.
Mounting Position: Type BNZ is completely filled,
voidfree, with mineral oil or silicone fluid impregnant, so that they
may be mounted and function in any position.
Terminations: Screw terminations can be placed in
virtually any location on the surface of the capacitors, observing
minimum spacing necessary to avoid terminal to terminal arcover.
How to Order.
Information required if applicable
- Specify peak voltage and working
voltage.
- Specify capacitance and tolerance.
- Indicate any physical limiting
dimensions.
- Almost every application requires
some voltage variation or ripple on the capacitor. Indicate the ripple
in peak-to-peak of RMS figures. The frequency of the ripple is also
very important.
- If the capacitor is to be used for
discharge or pulse coupling service it is desirable to know the
following:
a. peak current of discharge
b. time duration of discharge
c. voltage to which the capacitor discharges
d. amount of discharges per second or per minute
e. if a fault condition exists such that the capacitor might be
shorted through a very low impedance, (currents of over 50,000 amperes
peak are common)
- If the capacitor is to be used for
AC applications indicate:
a. frequency
b. current or voltage applied
- Duty cycle for AC and discharge
applications is important.
- Environment conditions such as
operating and storage temperature, vibration and shock, humidity,
etc... should be specified when ordering.
- Specify how the capacitor is to be
mounted - vertical or which plane of the horizontal.
- Specify if unit is to be operated
under gas or air - (indicate pressure) or under oil.
- Environmental conditions.
- Life expectancy required.
- Temperature. Operating and
non-operating.
Some examples of BNZ capacitors already
supplied are:
|
Part Number |
Voltage |
|
BNZ260-283B |
2600 V, RMS @
27-60KHZ, 50a RMS
.028mfd ±5%
Size: 6¾ x 4¾ x 5½ inches high |
|
BNZ900-203A |
9 KV, RMS @ 50Hz
.02mfd ±10%
Size: 4¾ x 1¾ x 8¾ inches high |
|
BNZ2700-123A |
27 KV, RMS @ 400Hz
.0125mfd -0, +20%
Size: 3¾ x 2¾ x 15 inches high |
|
BNZ5000-243A |
50 KV, RMS @ 200Hz
.024mfd ±5%
Size: 6¾ x 3¾ x 17½ inches high |
|