Go to the Home Page - IECI Logo

Interworld Electronics

 
and Computer Industries Inc.         
Interworld Electronics Home Page
Home   Data Acquisition   Pico   Product
PicoScope 9000
PicoScope 5000
PicoScope 3000
PicoScope 2000
ADC-200-100 
ADC-40/42/and ADC-100 
ADC-20 and ADC-24
ADC-212 and ADC-216  Precision PC Based Oscilloscope
USB Pen Scope
Software Options for the ADC-200
Palm to ADC-16 (Application Note)
Temperature & Humidity 
High Speed High Resolution ADC-212
DrDaq Low Cost Data Acquisition 
Automotive Products
Demo Software and Upgrades
Enviro Mon Data Logger for  temperature etc.
DrDaq Low Cost Data Acquisition 
PicoLog  Logging Software
Press Releases 
Technical tips
PicoScope 6 Video Demo

EnviroMon Alarms and Warning Systems

Converts PC to Oscilloscope (1435 bytes)
   


US Prices
CDN Prices

Privacy and Security

As well as recording data, EnviroMon can be configured to sound an alarm if a parameter goes out of range (high or low) or if a sensor fails.

There are four main alarms:

  • The EL-008 logger contains a built-in audible alarm - If the area where the logger is mounted is continuously manned, the built-in alarm is sufficient
  • Remote audible alarms - Use with EL-005 logger to provide an audible alarm, or anywhere on the network as an additional alarm with the EL-008 logger
  • Telephone Autodialler - Use to send telephone messages
  • SMS text messages - When connect to a GSM modem, the EL-005 logger can send text messages to a mobile phone.

EL-006 Remote Alarm

EL006 remote audio alarm

The 65dB EL-006 remote alarm is useful when the room where the logger is located is not often occupied. One or more remote alarms can be connected at any place along the network where staff would be able to hear the audible alarm.

 

EL-019 Autodialer

Gardiner Technology speach dialer

If it is necessary to respond to alarms when the site is unmanned, the alarm dialer module can make telephone calls to several numbers and deliver a voice message.

The EL-019 autodialer can be programmed with a list of emergency telephone numbers. When there is a problem, the dialer calls each of the telephone numbers in turn until someone answers, then it gives a message saying that there is a problem. The dialer behaves in the same way as any normal extension and does not affect the operation of other telephones connected to the same line.

The EL-019 is only suitable for use with UK phone systems. Overseas customers should contact their local distributor for a suitable alternative.

Supplied with the autodialer is the EL-018 adapter. The EL-018 serves three purposes:

  • it controls the dialer
  • it provides power for the dialer and for the system
  • it can provide battery backup for much longer periods than the logger's internal backup

The dialer adapter is supplied in a grey plastic box with a clear lid. The box has a large hole each side for cables. There is space for a 1.2AH battery inside the box: this will provide backup for 12 to 24 hours, depending on the configuration. Alternatively the unit can be connected to a larger, 12V lead acid battery (for example a car battery) outside the box: this could provide backup for many days.

The Speech Dialer can give three messages for different types of problem:

  • temperature out of range or sensor fail
  • mains fail for more than five minutes
  • network fail for more than five minutes
 

Alarm Options

When the EnviroMon network is being set up there are several alarm options that can be configured for each sensor.

High and Low Threshold

Alarms can be enabled or disabled for each sensor.
Enabled sensors can have both high and low thresholds.
It may be desirable to have an alarm on sensor failure, but not if a parameter goes out of range. This can be done by leaving the alarm enabled and setting a wide parameter range.

Hold Off

If the parameter normally goes out of range for short periods, it is possible to hold off (delay) alarms for a specified period. For example, if a freezer periodically goes through a defrost cycle lasting 15 minutes, an alarm holdoff of 20 minutes would prevent the defrost cycle from causing alarms.

Disable

If it is necessary to keep the parameter in range only during working hours, it is possible to specify the time range and days of the week that the alarm should be enabled. It is also possible to disable the alarm during holiday periods.

Put Links and images as needed here
 

Return to top of page


 USA Office: Tel: 1-877-902-2979    Fax: 1-877-FAX-IECI     Pacific  Time Zone    
                   Tel:1-425-223-4311    Fax: 1-425-223-4303     Pacific Time Zone
P.O. Box 1280. Street Address: 145 Tyee Drive, Point Roberts, WA 98281

Sales inquiries to:  sales at interworldusa.com  Support & Service: support at interworldusa.com

Western Canada: - Vancouver, B.C. Tel: 1-(604) 925-6150    Fax: 1-(604) 925-6170 Toll Free:1-(800) 663-6001

    2454 Haywood Ave, West Vancouver, B.C. V7V 1Y1
  Eastern Canada: - Markham, Ontario Tel: 1-(905) 513-7027    Fax: 1-(905) 513-7029 Toll Free:1-(800) 465-0164
3555 14th Ave, Unit 12, Markham, Ontario L3R 0H5

Sales inquiries to:  sales at interworld.ca    Support & Service: support at interworld.ca

To visit our Australian web site, please click here.