  Introduction Return to top of page

Simple configuration, easy programming and supported by major DA & C packages - these are just a few reasons to use Advantech's ADAM 4000 modules.

The 4½ digit LED display on the back of the ADAM-4014 lets you monitor process readings right at their source. The module displays readings in a wide variety of data formats as well as high-low alarm messages. The ADAM-4014D offers flexibility, ease of installation and direct availability of process data.

The ADAM-4014D includes an isolated loop power source. This lets you drive 2- or 3-wire transmitter with out an external power source. The module provides individual power loops for each channel, simplifying wiring while maintaining isolation between connected transmitters.

The ADAM-4014D can convert linear input to engineering units and show them on its built in LED display(direct display). When the input is nonlinear, data is first sent to the host computer for conversion to engineering units. The host computer sends the data back to the ADAM-4014D to show the module's LED display (remote display).

ADAM's built in checksum feature ensures data integrity by detecting communication errors. This feature adds two checksum characters to every command or response string that enable you to verify that the message received is exactly the same as the message sent.

Easy-to-use menu-driven utility software make configuration and calibration a snap. Its terminal emulation program lets you easily read from and write to ADAM modules. Writing application programs with this software (GENIE 2.0) is simple, you can learn the basics in just a few minutes.

Applications Return to top of page

  •  Critical process monitoring

Specifications Return to top of page

Communication

  • RS-485 (2-wire) to host
  • Speeds: 1200, 2400, 4800, 9600, 19200 bps
  • Max. communication distance: 4000feet (1.2Km)
  • Power and communication LED indicator
  • ASCII command/response protocol
  • Communication error checking with checksum
  • Asynchronous data format: 1 start bit, 8 data bits, 1 stop bit, no parity
  • Up to 256 multidrop modules per serial port
  • On-line module insertion and removal
  • Transient suppression on RS-485 communication lines

Power Requirements

  • Unregulated +10 +30 VDC
  • Protected against power reversal

Mechanical

  • Case: ABC with captive mounting hardware
  • Plug-in screw terminal block:
    Accepts 0.5 mm² to 2.5 mm²
    1-#12 or 2-#14 to #22 AWG

Environment

  • Operating temperature: 14 to 158ºF (-1000 to 70ºC)
  • EMI: Meets FCC Class A
  • Storage temperature: -13 to 185ºf (-25 to 85ºC)
  • Humidity: 5 to 95%, non-condensing

Analog Input Return to top of page

  • Input type: mV, V or mA
  • Input range: ±150 mV, ±500 mV, ±1V, ±5V, ±10 V, ±20 mA

Display

  • LED indicator: 4½-digit readout

Characteristics

  • Isolation voltage: 500 VDC
  • Sampling rate: 10 samples/sec
  • Bandwidth: 4 Hz
  • Accuracy: ±0.05% or better
  • Zero drift: ±0.3 µV/°C
  • Span drift: ±25 ppm/oC
  • CMR @ 50/60 Hz: 150 dB
  • NMR @ 50/60 Hz: 100 dB
  • Isolated loop power: +15VDC @ 30mA, Rload=125 OHM
  • Linear scaling

Digital Input

  • Channels: 1
  • Logic level 0: +1 V max.
  • Logic level 1: +3.5 V ~ +30 V
  • Pull up current: 0.5 mA
  • Event counter: Max. input frequency: 50 Hz Min. input pulse width: 0.5 msec

Digital Output

  • Channels: 2 Open collector to 30 V, 30 mA max. load
  • Power dissipation: 300 mW

Power

  • Power requirements: +10 to +30 V (non-regulated)
  • Power consumption: 1.8 W

 

Ordering Information Return to top of page

ADAM 4014D
Analog Input Module with LED Display

Return to top of page


 USA Office: Tel: 1-877-902-2979    Fax: 1-877-FAX-IECI     Pacific  Time Zone    
                   Tel:1-425-223-4311    Fax: 1-425-223-4303     Pacific Time Zone
P.O. Box 1280. Street Address: 145 Tyee Drive, Point Roberts, WA 98281

Sales inquiries to:  sales at interworldusa.com  Support & Service: support at interworldusa.com

Western Canada: - Vancouver, B.C. Tel: 1-(604) 925-6150    Fax: 1-(604) 925-6170 Toll Free:1-(800) 663-6001

    2454 Haywood Ave, West Vancouver, B.C. V7V 1Y1
  Eastern Canada: - Markham, Ontario Tel: 1-(905) 513-7027    Fax: 1-(905) 513-7029 Toll Free:1-(800) 465-0164
3555 14th Ave, Unit 12, Markham, Ontario L3R 0H5

Sales inquiries to:  sales at interworld.ca    Support & Service: support at interworld.ca

To visit our Australian web site, please click here.