Go to the Home Page - IECI Logo

Interworld Electronics

 
and Computer Industries Inc.         
Interworld Electronics Home Page
  Your ALT-Text here Home    Your ALT-Text here Data Acquistion    Your ALT-Text here Advantech    Your ALT-Text here ADAM   Your ALT-Text here 4012
Remote Data Acquisition & Control (ADAM
Digital I/O Cards
PC-Based Industrial Workstations
Industrial PC Chassis
Industrial Communication Cards (ICOM)
Download Utility Software
Software
ADAM-4012  Your ALT-Text here
adam-4012 image
Analog Input Module


 

Introduction
Applications
Specifications
Ordering Information
Put Links and images as needed here
  Introduction Return to top of page

Simple configuration, easy programming and supported by major DA & C packages - these are just a few reasons to use Advantech's ADAM 4000 modules.

Analog input modules use microprocessor-controlled high resolution 16-bit sigma-delta A/D converters to acquire sensor signals such as voltage, current, thermocouple or RTD. They then translate digital data into one of the following formats: engineering units, % of FSR, two's complement for Ohms. After the modules receive a request from the host, they send the data in the desired format over the RS-485 network.

ADAM analog input modules protect your equipment from ground loops by providing 500VDC isolation. All analog input modules feature digital inputs and outputs which may also be used for alarm and event counting.

You can use any high-level language with ASCII-based string functions (such as C, Pascal or BASIC) to communicate with ADAM modules or process their data. For example, the command and response for an analog input module would be: COMMAND: #5, RESPONSE: >+4.834. This command requests the data stored by the module with address 05 (Hex). The module responds with the value +4.834 V.

ADAM's built in checksum feature ensures data integrity by detecting communication errors. This feature adds two checksum characters to every command or response string that enable you to verify that the message received is exactly the same as the message sent.

Easy-to-use menu-driven utility software make configuration and calibration a snap. Its terminal emulation program lets you easily read from and write to ADAM modules. Writing application programs with this software (GENIE 2.0) is simple, you can learn the basics in just a few minutes.

Applications Return to top of page

  • Multiple channel DC voltage measurement

Specifications Return to top of page

Communication

  • RS-485 (2-wire) to host
  • Speeds: 1200, 2400, 4800, 9600, 19200 bps
  • Max. communication distance: 4000feet (1.2Km)
  • Power and communication LED indicator
  • ASCII command/response protocol
  • Communication error checking with checksum
  • Asynchronous data format: 1 start bit, 8 data bits, 1 stop bit, no parity
  • Up to 256 multidrop modules per serial port
  • On-line module insertion and removal
  • Transient suppression on RS-485 communication lines

Power Requirements

  • Unregulated +10 +30 VDC
  • Protected against power reversal

Mechanical

  • Case: ABC with captive mounting hardware
  • Plug-in screw terminal block:
    Accepts 0.5 mm² to 2.5 mm²
    1-#12 or 2-#14 to #22 AWG

Environment Return to top of page

  • Operating temperature: 14 to 158ºF (-1000 to 70ºC)
  • EMI: Meets FCC Class A
  • Storage temperature: -13 to 185ºf (-25 to 85ºC)
  • Humidity: 5 to 95%, non-condensing

Analog Input

  • Input type: mV, V or mA
  • Input range: ±150 mV, ±500 mV, ±1V, ±5V, ±10 V, ±20 mA

Characteristics

  • Isolation voltage: 500 VDC
  • Sampling rate: 10 samples/sec
  • Bandwidth: 4 Hz
  • Accuracy: ±0.05% or better
  • Zero drift: ±0.3 µV/°C
  • Span drift: ±25 ppm/°C
  • CMR @ 50/60 Hz: 150 dB
  • NMR @ 50/60 Hz: 100 dB

Digital Input

  • Channels: 1
  • Logic level 0: +1 V max.
  • Logic level 1: +3.5 V ~ +30 V
  • Pull up current: 0.5 mA
  • Event counter: Max. input frequency: 50 Hz Min. input pulse width: 0.5 msec

Digital Output

  • Channels: 2 Open collector to 30 V, 30 mA max. load
  • Power dissipation: 300 mW

Power

  • Power requirements: +10 to +30 V (non-regulated)
  • Power consumption: 1.2 W

 

Ordering Information Return to top of page

ADAM 4012

Analog Input Module (mV, V, mA)

Return to top of page


 USA Office: Tel: 1-877-902-2979    Fax: 1-877-FAX-IECI     Pacific  Time Zone    
                   Tel:1-425-223-4311    Fax: 1-425-223-4303     Pacific Time Zone
P.O. Box 1280. Street Address: 145 Tyee Drive, Point Roberts, WA 98281

Sales inquiries to:  sales at interworldusa.com  Support & Service: support at interworldusa.com

Western Canada: - Vancouver, B.C. Tel: 1-(604) 925-6150    Fax: 1-(604) 925-6170 Toll Free:1-(800) 663-6001

    2454 Haywood Ave, West Vancouver, B.C. V7V 1Y1
  Eastern Canada: - Markham, Ontario Tel: 1-(905) 513-7027    Fax: 1-(905) 513-7029 Toll Free:1-(800) 465-0164
3555 14th Ave, Unit 12, Markham, Ontario L3R 0H5

Sales inquiries to:  sales at interworld.ca    Support & Service: support at interworld.ca

To visit our Australian web site, please click here.